Welcome to the official website of Qingdao Xinpufa Fluid Technology Co., Ltd
English   |   中文版

TEL:

139-6425-0935

WS Series Gas Water Separator

More than 99% of liquid water can be removed through the high-efficiency cyclone gas water separator, which protects the dryer and post-treatment filter to a certain extent, and improves the performance of these equipment; Reduce corrosion of pipes and damage to valves, cylinders, electronic components and other equipment caused by water; Protect the prefilter of the cold dryer and the suction dryer; Protect the filter from liquid contamination; More than 99% of liquid water can be removed by installing YUKA's high-efficiency cyclone gas water separator, which protects the dryer and post-treatment filter to a certain extent and improves the performance of these equipment; Reduce corrosion of pipes and damage to valves, cylinders, electronic components and other equipment caused by water; Protect the prefilter of the cold dryer and the suction dryer; Protect the filter from liquid contamination; Efficient removal of liquid from compressed air; Improve air quality.

ModelPipe diameterFlowOutline specification(mm)
L/Sm3/minscfmWDHABC(Reserved space for installation)
WS 15RC1/2"40.02.484.5897922840186118
WS 25RC3/4"60.03.6127.1897922840186118
WS 50RC1"75.04.5158.9897926340220158
WS 75RC1"125.07.5264.812011033555276195
WS 100RC1-1/2"166.710.0353.112011033555276195
WS 200RC2"300.118.0635.616415156464566480
WS 250RC2-1/2"416.825.0882.816415166464566480
WS 700RC2-1/2"700.042.01483.120018971278634560
WS 800RC3"833.550.01765.620018971278634560
WS 800FDN80/DN100833.550.01765.6280189734/74478634560
WS 1000FDN100/DN1251000.260.02118.7280189780/79578634560
WS 1200FDN100/DN1251166.770.02464.02801891058/107378889780
Technical requirements:Maximum working pressure: 10 barg; Maximum operating temperature: 80 ° C; Minimum operating temperature: 1.5 ° C


PressureBarg12345678910111213141516
Psig152944597387100116131145160174189203219232
Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51
ModelPipe diameterFlowOutline specification(mm)
L/Sm3/minscfmWDHABC(Reserved space for installation)
WS 15RC1/2"40.02.484.5897922840186118
WS 25RC3/4"60.03.6127.1897922840186118
WS 50RC1"75.04.5158.9897926340220158
WS 75RC1"125.07.5264.812011033555276195
WS 100RC1-1/2"166.710.0353.112011033555276195
WS 200RC2"300.118.0635.616415156464566480
WS 250RC2-1/2"416.825.0882.816415166464566480
WS 700RC2-1/2"700.042.01483.120018971278634560
WS 800RC3"833.550.01765.620018971278634560
WS 800FDN80/DN100833.550.01765.6280189734/74478634560
WS 1000FDN100/DN1251000.260.02118.7280189780/79578634560
WS 1200FDN100/DN1251166.770.02464.02801891058/107378889780
Technical requirements:Maximum working pressure: 10 barg; Maximum operating temperature: 80 ° C; Minimum operating temperature: 1.5 ° C


PressureBarg12345678910111213141516
Psig152944597387100116131145160174189203219232
Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51

Fill in the information

139-6425-0935