Welcome to the official website of Qingdao Xinpufa Fluid Technology Co., Ltd
English   |   中文版

TEL:

139-6425-0935

Oil injection screw air compressor

High reliability and low operation cost

The most direct way to improve the profit margin is to reduce operating costs. As we all know, energy costs account for 80% of the whole life cycle cost of a compressor. Atlas Copco GA series compression The engine is equipped with an intelligent fuel injection system and IE4/IE5 motor, which can reduce the operating cost of customers The machine can also operate stably under severe working conditions.

GA 90+ - 160 (50 Hz)

ModelMaximum working pressureFlow(1)Motor powerOutlet sizeWeight
StandardFull performance(2)StandardStandardFull performance(2)
bar(e)psigbar(e)psigl/sm3/mincfmkw
kglbskglbs
GA90+ - 5.55.5805.37735421.375090G 3''2721599929716550
GA90+ - 7.57.51097.310629717.8629
GA90+ - 8.58.51238.312028317.0600
GA90+ - 10101459.814225815.5547
GA110 - 5.55.5805.37742625.5901110G 3''2802617730526728
GA110 - 7.57.51097.310636922.2782
GA110 - 8.58.51238.312034620.8734
GA110 - 10101459.814231518.9667
GA132 - 5.55.5805.37750330.21065132G 3''2885636031356911
GA132 - 7.57.51097.310644126.5934
GA132 - 8.58.51238.312041424.8877
GA132 - 10101459.814238122.9807
GA160 - 7.57.51097.310652631.61114160G 3''2963653232137083
GA160 - 8.58.51238.312049529.71048
GA160 - 10101459.814245927.5972

(1) Unit performance parameters are measured according to ISO 1217, Appendix C, Rev. 4 (2009).

Reference working condition:

- The absolute intake pressure is 1 bar (14.5 psi).

- The intake air temperature is 20 ° C (68 ° F).

(2) Built in cold dryer (FF): the pressure dew point under the reference working condition is 3 ° C (37 ° F).



FAD (1) is measured at the following working pressures:
ModelStandardFull performance
5.5bar5 bar5 bar
7.5bar
7 bar7 bar
8.5bar
8 bar8 bar
10 bar
10 bar9.8 bar


Size

LongWideHigh

mmmmmm
GA 90+-160250017852020
GA 90+-160 FF290017852020


GA 110 – 160 VSD+ (60 Hz)

ModelMaximum working pressureFlow(1)Motor powerOutlet sizeWeight
StandardFull performance(2)StandardStandardFull performance(2)
bar(e)psigbar(e)psigl/sm3/mincfmkw
kglbskglbs
GA110VSD+ - 8.58.51238.312096-4095.8-24.5206-866110G 3''2300507125505622
GA110VSD+ - 10101459.814296-3365.8-20.2206-712110G 3''2300507125505622
GA132VSD+ - 8.58.51238.312096-4885.8-29.3206-1035132G 3''2416532626665877
GA132VSD+ - 10101459.814296-4035.8-24.2206-853132G 3''2416532626665877
GA160VSD+ - 8.58.51238.312096-5945.8-35.6206-1258160G 3''2450540127005952
GA160VSD+ - 10101459.814296-4925.8-29.5206-1042160G 3''2450540127005952

(1) Unit performance parameters are measured according to ISO 1217, Appendix C, Rev. 4 (2009).

Reference working condition:

- The absolute intake pressure is 1 bar (14.5 psi).

- The intake air temperature is 20 ° C (68 ° F).

(2) Built in cold dryer (FF): the pressure dew point under the reference working condition is 3 ° C (37 ° F).


Size

LongWideHigh

mmmmmm
GA 90+-160 VSD+250017852020
GA 90+-160 VSD+ FF290017852020

GA 90+ - 160 (50 Hz)

ModelMaximum working pressureFlow(1)Motor powerOutlet sizeWeight
StandardFull performance(2)StandardStandardFull performance(2)
bar(e)psigbar(e)psigl/sm3/mincfmkw
kglbskglbs
GA90+ - 5.55.5805.37735421.375090G 3''2721599929716550
GA90+ - 7.57.51097.310629717.8629
GA90+ - 8.58.51238.312028317.0600
GA90+ - 10101459.814225815.5547
GA110 - 5.55.5805.37742625.5901110G 3''2802617730526728
GA110 - 7.57.51097.310636922.2782
GA110 - 8.58.51238.312034620.8734
GA110 - 10101459.814231518.9667
GA132 - 5.55.5805.37750330.21065132G 3''2885636031356911
GA132 - 7.57.51097.310644126.5934
GA132 - 8.58.51238.312041424.8877
GA132 - 10101459.814238122.9807
GA160 - 7.57.51097.310652631.61114160G 3''2963653232137083
GA160 - 8.58.51238.312049529.71048
GA160 - 10101459.814245927.5972

(1) Unit performance parameters are measured according to ISO 1217, Appendix C, Rev. 4 (2009).

Reference working condition:

- The absolute intake pressure is 1 bar (14.5 psi).

- The intake air temperature is 20 ° C (68 ° F).

(2) Built in cold dryer (FF): the pressure dew point under the reference working condition is 3 ° C (37 ° F).



FAD (1) is measured at the following working pressures:
ModelStandardFull performance
5.5bar5 bar5 bar
7.5bar
7 bar7 bar
8.5bar
8 bar8 bar
10 bar
10 bar9.8 bar


Size

LongWideHigh

mmmmmm
GA 90+-160250017852020
GA 90+-160 FF290017852020


GA 110 – 160 VSD+ (60 Hz)

ModelMaximum working pressureFlow(1)Motor powerOutlet sizeWeight
StandardFull performance(2)StandardStandardFull performance(2)
bar(e)psigbar(e)psigl/sm3/mincfmkw
kglbskglbs
GA110VSD+ - 8.58.51238.312096-4095.8-24.5206-866110G 3''2300507125505622
GA110VSD+ - 10101459.814296-3365.8-20.2206-712110G 3''2300507125505622
GA132VSD+ - 8.58.51238.312096-4885.8-29.3206-1035132G 3''2416532626665877
GA132VSD+ - 10101459.814296-4035.8-24.2206-853132G 3''2416532626665877
GA160VSD+ - 8.58.51238.312096-5945.8-35.6206-1258160G 3''2450540127005952
GA160VSD+ - 10101459.814296-4925.8-29.5206-1042160G 3''2450540127005952

(1) Unit performance parameters are measured according to ISO 1217, Appendix C, Rev. 4 (2009).

Reference working condition:

- The absolute intake pressure is 1 bar (14.5 psi).

- The intake air temperature is 20 ° C (68 ° F).

(2) Built in cold dryer (FF): the pressure dew point under the reference working condition is 3 ° C (37 ° F).


Size

LongWideHigh

mmmmmm
GA 90+-160 VSD+250017852020
GA 90+-160 VSD+ FF290017852020

Fill in the information

139-6425-0935