National high-tech enterprise focusing on post-treatment and purification system of compressed air and medical gas system. It has the ability of completely independent research and development, has applied for/obtained nearly 100 patents, and has formed a three-dimensional intellectual property protection system. Its products are sold to foreign countries and won many awards. He is responsible for formulating a number of national and industrial standards. For the purification and post-treatment of compressed gas and the research, development and production of medical gas system. Product scope: freezing dryer, adsorption dryer, pipeline precision filtration, oxygen generator, nitrogen generator, gas water separator, filter element, pneumatic element, etc.

ModelMaximum handling capacityInput powerInterface sizePower SupplyWeight KGOverall dimensions
HL-1WR1.20.5RC1"220V50HZ135670x360x1265
HL-2WR2.40.8RC1H220V50HZ170780x360x1485
HL-3WR3.81RC1"220V50HZ240850x400x1385
HL-6WR6.51.8RC1-1/2"220V50HZ2851000x450x1700
HL-8WR8.52.4RC2"220V50HZ2551100x500x2050
HL-10WR11.53RC2"380V50HZ5261200x500x2030
HL-13WR13.53RC2"380V50HZ6051300x500x2230
HL-15WR17.04.5DN65380V50HZ7121300x560x2360
HL-20WR23.06DN80380V50HZ8481400x560x2530
HL-25WR27.07.5DN80380V50HZ11501650x820x2630
HL-30WR33.09DN80380V50HZ13281750x900x2630
HL-40WR40.012DN100380V50HZ16741850x750x2650
HL-50WR55.015DN100380V50HZ21001950x850x2650
HL-60WR65.018DN125380V50HZ27072200x1240x2705
HL-80WR85.024DN150380V50HZ35732420x1260x2800
HL-100WR110.030DN150380V50HZ46392500x1100x2750
HL-120WR130.036DN150380V50HZ51002650x1200x2800
HL-150WR160.045DN200380V50HZ55862800x1300x2900




Inlet pressure Mpa0.420.490.560.630.700.770.840.910.981.051.231.411.581.76
Pressure correction factor0.650.740.830.911.001.041.081.121.161.201.291.371.451.52


Intake air temperature °C1520253035384245
Pressure correction factor1.211.161.121.071.031.000.840.72


Selection of adsorption dryer:


Temperature correction coefficient C
Maximum intake air temperature°C253035404550
CFT1110.970.880.73


Pressure correction factor CFP
Minimum intake pressureBarg456788910111213
CFP0.630.750.881.001.131.251.251.381.501.631.75


Dewpoint correction factor CFD
Required dew point CFD°C (°F)-20(-4)-40(-40)-70(-100)
CFD1.11.10.7


After selecting the minimum inlet pressure correction factor (CFP) of the dryer (when determining the minimum working pressure of the dryer, the pressure loss of the front equipment in the system must be considered), the maximum inlet test correction factor (CFT) of the dryer, and the dew point correction factor (CFD), the flow formula that the dryer should meet is calculated as follows:




Select the dryer model from the table according to the minimum flow that the dryer should meet, and ensure that the flow of the selected model is at least equal to or greater than this.
ModelMaximum handling capacityInput powerInterface sizePower SupplyWeight KGOverall dimensions
HL-1WR1.20.5RC1"220V50HZ135670x360x1265
HL-2WR2.40.8RC1H220V50HZ170780x360x1485
HL-3WR3.81RC1"220V50HZ240850x400x1385
HL-6WR6.51.8RC1-1/2"220V50HZ2851000x450x1700
HL-8WR8.52.4RC2"220V50HZ2551100x500x2050
HL-10WR11.53RC2"380V50HZ5261200x500x2030
HL-13WR13.53RC2"380V50HZ6051300x500x2230
HL-15WR17.04.5DN65380V50HZ7121300x560x2360
HL-20WR23.06DN80380V50HZ8481400x560x2530
HL-25WR27.07.5DN80380V50HZ11501650x820x2630
HL-30WR33.09DN80380V50HZ13281750x900x2630
HL-40WR40.012DN100380V50HZ16741850x750x2650
HL-50WR55.015DN100380V50HZ21001950x850x2650
HL-60WR65.018DN125380V50HZ27072200x1240x2705
HL-80WR85.024DN150380V50HZ35732420x1260x2800
HL-100WR110.030DN150380V50HZ46392500x1100x2750
HL-120WR130.036DN150380V50HZ51002650x1200x2800
HL-150WR160.045DN200380V50HZ55862800x1300x2900




Inlet pressure Mpa0.420.490.560.630.700.770.840.910.981.051.231.411.581.76
Pressure correction factor0.650.740.830.911.001.041.081.121.161.201.291.371.451.52


Intake air temperature °C1520253035384245
Pressure correction factor1.211.161.121.071.031.000.840.72


Selection of adsorption dryer:


Temperature correction coefficient C
Maximum intake air temperature°C253035404550
CFT1110.970.880.73


Pressure correction factor CFP
Minimum intake pressureBarg456788910111213
CFP0.630.750.881.001.131.251.251.381.501.631.75


Dewpoint correction factor CFD
Required dew point CFD°C (°F)-20(-4)-40(-40)-70(-100)
CFD1.11.10.7


After selecting the minimum inlet pressure correction factor (CFP) of the dryer (when determining the minimum working pressure of the dryer, the pressure loss of the front equipment in the system must be considered), the maximum inlet test correction factor (CFT) of the dryer, and the dew point correction factor (CFD), the flow formula that the dryer should meet is calculated as follows:




Select the dryer model from the table according to the minimum flow that the dryer should meet, and ensure that the flow of the selected model is at least equal to or greater than this.

Fill in the information

139-6425-0935